Jump-Starting The Machine - Toro Workman HDX Series Operator's Manual

Table of Contents

Advertisement

1. Power outlet (10 A)
2. Switched power (10 A)
3. Fuel pump/supervisor
switch (10 A)
4. Horn/power point (15 A)

Jump-Starting the Machine

WARNING
Jump-starting can be dangerous. To avoid
personal injury or damage to electrical
components in machine, observe the
following warnings:
• Never jump-start with a voltage source
greater than 15 V DC; this damages the
electrical system.
• Never attempt to jump-start a discharged
battery that is frozen. It could rupture or
explode during jump-starting.
• Observe all battery warnings while
jump-starting your machine.
• Be sure your machine is not touching the
jump-start machine.
• Connecting cables to the wrong post could
result in personal injury and/or damage to
the electrical system.
1.
Squeeze the battery cover to release the tabs
from the battery base and remove the battery
cover from the battery base
Figure 42
5. Lights/brake (15 A)
6. Hazard lights (10 A)
7. 4WD/transmission (10 A)
(Figure
43).
decal115-7813
1. Battery cover
2.
Connect a jumper cable between the positive
posts of the 2 batteries
Note:
+ sign on top of the battery cover.
3.
Connect 1 end of the other jumper cable to the
negative terminal of the battery in the other
machine.
Note:
battery cover.
Note:
jumper cable to the negative post of the
discharged battery. Connect the jumper cable to
the engine or frame. Do not connect the jumper
cable to the fuel system.
1. Battery
43
Figure 43
(Figure
The positive post may be identified by a
The negative terminal has "NEG" on the
Do not connect the other end of the
Figure 44
g010326
44).
g010325

Hide quick links: