WATER LEFT IN THE TANK AFTER
PUM P-OUT.
14 M ALFUNCTIONS SHOW N ON THE DISPLAY (FOR THE USER)
The dishw asher can show a series of malfunct ions on display.
Aft er t he machine has been sw it ched off and rest art ed, if t he problem is not solved, follow t he st eps below :
( FOR A M ORE PROFICIENT AFTER-SALES SERVICE, ALW AYS TAKE NOTE OF THE INDICATED ERROR )
Tank t em perature probe anom aly
Err04
Tank w at er filling anom aly
Err05
Wat er pum p-out anom aly
Err06
(w at er remains in t he dishw asher)
Err09
Excessive w ater level in t he t ank anom aly
Boiler heat ing anomaly (does not heat )
Err23
Boiler t em perat ure probe anomaly
Err24
Err25
Boiler w at er filling anom aly
Boiler em pt ying anom aly
Err26
Err27
Boiler em pt ying anom aly – w it h full t ank
Err28
Boiler heat ing anomaly (over t em perat ure)
Wast e t ube badly positioned or
part ially clogged.
Cont act After-sales Service
Check t hat t he w ater supply t ap is open, t he dynamic supply
pressure, cleanliness of t he inlet w at er filter. If t he problem
st ill occurs, cont act Aft er-sales Service.
Check t hat t he filters are clean, and t hat t he drain pipe is not
bent , obst ruct ed, narrow ed.
Check t hat t he drain pum p is not blocked wit h a foreign body,
follow st eps indicat ed in " 10.2 Periodical checks" .
If the problem st ill occurs, cont act Aft er-sales Service.
Cont act After-sales Service
Cont act After-sales Service
Cont act After-sales Service
Check t hat t he w ater supply t ap is open, t he dynamic supply
pressure, cleanliness of t he inlet w at er filter. If t he problem
st ill occurs, cont act Aft er-sales Service.
Check t hat t he nozzles of t he rinsing spray arm s are not
clogged.
If the problem st ill occurs, cont act Aft er-sales Service.
Cont act After-sales Service
Cont act After-sales Service
19.390.7159.00
Rev. M anuale
36
posit ioned t oo high; see connection
schem e.
Verify t hat the tube and drainage are not
clogged and that t he drainage is not
posit ioned t oo high; see connection
schem e.