Option Menu
Color Alarm
Shop for Fluke products online at:
Table 11. Image Menu (cont.)
Option
Turns on/off the high-temperature color alarm. The high-
temperature color alarm shows a full visible image and only
High Alarm OFF
shows infrared information on objects or areas that are
above the set apparent temperature level.
Turns on/off the low-temperature (or dew point) color alarm.
The low-temperature color alarm shows a full visible image
Low Alarm OFF
and only shows infrared information on objects or areas that
are below the set apparent temperature level.
Sets the high apparent temperature level. Requires the
Set High Alarm
High Alarm to be on.
Sets the low apparent temperature level. Requires the Low
Alarm to be on.
Set Low Alarm
Shows color isotherms, or infrared information, outside of a
set of both high and low limits. Requires High Alarm and
Outside
Low Alarm to be on and temperature levels for both alarms
to be set.
Shows color isotherms, or infrared information, inside of a
set of both high and low limits. Requires High Alarm and
Inside
Low Alarm to be on and temperature levels for both alarms
to be set.
MyFlukeStore
www.
Expert Series Thermal Imagers
Description
Note
The Imager does not sense ambient or surface
dew point level automatically. To use the low-
temperature color alarm function as a dew point
color alarm, determine and input the surface
dew point temperature. The colors presented
can help identify areas of concern with possible
dew point condensation.