1
2
3
4
5
Publication History
Print Date Pub No. ECO No.
Jan. 99
7C8772
7C8772 – 12JAN99
6
Check the incoming water temperature. Temperature must be between 4.4
°
°
(40
F) and 29.4
C (85
Check that the correct BULB and SAFELIGHT FILTER are in the
SAFELIGHT and at the correct distance from the FEED SHELF and work
surface.
Check that the TOP COVER and PANELS are tight on the PROCESSOR.
Check that there are no leaks in the LIGHTTIGHT GASKET.
10 x 10 cm films - feed films diagonally if they fail to transport reliably.
Check the time delay. For all transport speeds, the BUZZER should sound once
the trailing edge of the film has advanced 75 mm (3 in.) into the PROCESSOR.
Check that the solution levels of the TANKS are at the overflow WEIRS.
Check for solution in the REPLENISHMENT TANKS. Fill if necessary.
NOTE: Mix developer replenisher in quantities not to exceed a 2-week
supply.
With a THERMOMETER of known accuracy, check that the temperature of the
developer is correct. If necessary, have qualified service personnel make
adjustments.
NOTE: Check the incoming water temperature. It must be a minimum of 4
°
(7
F) lower than the desired developer temperature.
Affected
Pages
N/A
All
1. Transport Failure
2. Surface Artifacts
3. Abnormal Film Densities
4. Wet Films
5. Low Solution Levels
6. Overlapping of Films
°
F).
File Name
sm3554_1_12jan99.fm
Correcting Problems
°
C
°
C
Notes