PLUMBING
[1] Check components and connections for leakage:
• RECIRCULATION PUMPS
• VALVES
• TUBING
• TANKS
[2] Check that the temperature of the water supply is 4-30
WATER
INLET
TUBE
[3] Check the flow rate of the water supply:
(a) Drain the TANKS.
(b) Remove:
• FIXER/WASH CROSSOVER
• DRYER RACK
• WASH RACK
(c) Start the water supply.
(d) Measure the flow rate at the WATER INLET TUBE. The rate should be 946 mL/min. (1/4 gal/min.),
+10%, -0%.
RECIRCULATION PUMPS
Caution
Do not operate the RECIRCULATION PUMP if the TANKS are empty.
[1] Actuate the RECIRCULATION PUMPS.
[2] Check for:
• leakage
• agitation of the solution in the TANKS
• excessive noise from the RECIRCULATION PUMPS