[6] Apply SEALANT TL-3230 to the THREADS on the new DEVELOPER OVER-TEMPERATURE
THERMOSTAT.
DEVELOPER
THERMISTOR
Caution
You must install the DEVELOPER OVER-TEMPERATURE THERMOSTAT at the correct distance from the
THERMOWELL.
[7] Install the new DEVELOPER OVER-TEMPERATURE THERMOSTAT 5 mm (13/64 in.) from the
THERMOWELL.
[8] Connect the wires of the new DEVELOPER OVER-TEMPERATURE THERMOSTAT to:
• TB4-8
• TB4-9
• TB4-15
• TB4-16
[9] Close the ELECTRICAL BOX.
[10] Fill the DEVELOPER TANK or remove the CLAMPS from the TUBES on the THERMOWELL.