DDS 5900 Digital Discussion System
Pin
Function
1
In-going +
2
In-going -
3
+48V
4
0V
5
0V
6
+48V
7
Outgoing -
8
Outgoing +
If other color codes are used then the four pairs are connected as follows:
Pair 2: Pin 1 & 2
Pair 3: Pin 3 & 6
Pair 1: Pin 4 & 5
Pair 4: Pin 7 & 8
The phase of the pairs must be correct and the wiring specification EIA 568-B (Cat5e).
Cat6 and Cat7 cables are normally only be terminated in sockets (female) and not in cable plugs.
Cat6 and Cat7 can only be used for feeding cables terminating in wall outlets or patch panels.
Analog Audio Out
XLR3 male
Pin
Signal
1
2
3
Analog Audio In
XLR3 female
Connector #1
ORG/WHT
ORG
GRN/WHT
BLU
BLU/WHT
GRN
BRN/WHT
BRN
Earth
Signal +
Signal –
Connector #2
ORG/WHT
ORG
GRN/WHT
BLU
BLU/WHT
GRN
BRN/WHT
BRN
Cable type
2 x 0.25 mm2 shielded.