DDS 5900 Digital Discussion System
Cable length from
CCU to the first unit
10 m
30 m
50 m
100 m
2 Chains, 4 Units per JB 6104
Cable length from
CCU to the first unit
10 m
30 m
50 m
100 m

Installing Large Systems

Power Supplies for Additional Components
To add additional components to the system, add an inline or rackmount power supply to the discussion unit chain.
Inline Power Supply
Use the PI-6000 power inserter to add an inline power supply for approximately 50 more discussion units. The unit
may be connected at any point in the chain to power the additional components. Multiple PI-6000 units can be
used to reach the maximum 250 supported discussion units.
Note: The PI-6000 does not refresh the data signal, so total cable length cannot exceed 120 m.
Cable Length Between
each JB 6104
3 m
3 m
3 m
3 m
Cable Length Between
each JB 6104
5 m
5 m
5 m
5 m
Number of JB 6104
22
20
20
14
Number of JB 6104
13
12
12
10
Shure Incorporated
Maximum Number of DUs
42
40
38
28
Maximum Number of DUs
50
48
46
40