Carrier 140/E Series Installation, Start--Up, Operating, And Service And Maintenance page 39

Table of Contents

Advertisement

Table
14 - 2-Stage
Furnace
Blower
OFF delay Setup
Switch
DESIRED HEATING MODE
SETUP SWITCH
SETUP SWITCH
BLOWER OFF DELAY (SEC.)
SW-2
SW-3
90
OFF
OFF
120
OFF
ON
150
ON
OFF
180
ON
ON
SUBBASE
TERMINALS
WITH
THERMOSTAT
REMOVED
(ANITICIPATOR,
CLOCK, ETC.,
MUST BE OUT OF CIRCUIT.)
AMMETER
I0 TURNS
FROM UNIT 24-V
CONTROL TERMINALS
EXAMPLE;
5.0 AMPS ON AMMETER
= 0.5 AMPS FOR THERMOSTAT
10 TURNS AROUND
JAWS
ANTICIPATOR
SETTING
A96316
Fig. 50 - Amp. Draw Check with Ammeter
Step 4
--
Check
Safety
Controls
The flame sensor,
gas valve,
and pressure
switch were all checked
in the Start-up
procedure
section as part of normal operation.
1. Check Main Limit Switch(es)
This
control
shuts
off combustion
system
and energizes
air-circulating
blower
motor,
if furnace
overheats.
By us-
ing this method
to check limit control, it can be established
that limit is flmctioning
properly
and will operate
if there
is a restricted
return-air
supply
or motor
failure.
If limit
control
does not flmction
during
this test, cause
must be
determined
and corrected.
a. Run furnace
for at least 5 minutes.
b. Gradually
block
off return air with a piece of cardboard
or sheet metal until the limit trips.
c. Unblock
return air to permit normal
circulation.
d. Burners
will re-light
when furnace
cools down.
2. Check draft safeguard
switch.
The purpose
of this control
is to cause the safe shutdown
of the furnace
during
certain blocked
vent conditions.
a. Verify vent pipe is cool to the touch.
b. Disconnect
power
to furnace
and remove vent connector
from furnace
vent elbow.
c. Restore
power to furnace and set room thermostat
above
room temperature.
d. After normal
start-up,
allow
furnace
to operate
for 2
minutes,
then block vent elbow in furnace
80% of vent
area with a piece of flat sheet metal.
e. Furnace
should cycle offwithin
2 minutes.
If gas does not
shut off within
2 minutes,
determine
reason
draft safe-
guard switch did not flmction properly and correct condi-
tion.
f. Remove blockage from furnace vent elbow.
g. Switch will auto-reset when it cools.
h. Re-install vent connector.
NOTE:
Should switch remain open longer than 3 minutes,
furnace control board will lockout the furnace for 3 hours. To
reset furnace
control
board,
turn thermostat
below
room
temperature or from HEAT to OFF and turn 115-v power OFF,
then back ON.
3. Check Pressure Switch(es)
This control proves operation of the draft inducer blower.
a. Turn off 115-v power to furnace.
b. Disconnect inducer motor lead wires from wire harness.
c. Turn on 115-v power to furnace.
d. Set thermostat to "call for heat" and wait I minute. When
pressure switch is functioning properly, hot surface ig-
niter should NOT glow and control diagnostic light
flashes a status code 32. If hot surface igniter glows when
inducer motor is disconnected, shut down furnace imme-
diately.
e. Determine reason pressure switch did not function prop-
erly and correct condition.
f, Turn off 115-v power to furnace,
g. Reconnect inducer motor wires, replace outer door, and
turn on 115-v power.
h. Blower will run for 90 seconds before beginning the call
for heat again.
i. Furnace should ignite normally.
Step 5 -- ChecMist
1. Put away tools and instruments. Clean up debris.
2. Verify that switches
for LHT
and OFF-DELAY
are
blower OFF-DELAY
are selected as desired.
3. Verify that blower and burner access doors are properly in-
stalled.
4. Cycle test furnace with room thermostat.
5. Check operation of accessories per manufacturerDfs in-
structions.
6. Review User's Guide with owner.
7. Attach literature packet to furnace.
39