ACCESSORIES
1. Electronic
Air Cleaner
(EAC)
Connect
an accessory
Electronic
Air Cleaner
(if used) us-
ing 1/4-in
female quick
connect
terminals
to the two male
1/4-in
quick-connect
terminals
on
the
control
board
marked
EAC-1
and EAC-2.
The terminals
are rated for
115VAC,
1.0 amps
maximum
and are energized
during
blower
motor operation.
(See Fig. 33.)
2. Humidifier
(HUM)
Connect
an accessory
24 VAC, 0.5 amp. maximum
hu-
midifier
(if used) to the 1/4-in
male quick-connect
HUM
terminal
and
COM-24V
screw
terminal
on the
control
board
thermostat
strip.
The HUM
terminal
is energized
when gas valve relay (GVR)
is energized.
(See Fig. 33.)
NOTE:
A field-supplied,
115-v
controlled
relay connected
to
EAC terminals
may be added if humidifier
operation
is desired
during blower
operation,
SETUP
SWITCHES
LOW-HEAT
ONLY AND
BLOWER
OFF-DELAY
\
24-V-THERMOSTAT
TERMINALS
TWINNING
AND/OR
COMPONENT
TEST
TERMINAL
/
\
HUMIDIFIER TERMINAL
(24-VAC 0.5 AMP MAX.)
3-AMP FUSE
LED OPERATION &
DIAGNOSTIC LIGHT
115-VAC (L2) NEUTRAL _
NOTE:
DO
NOT
connect
furnace
control
HUM
terminal
to
HUM
(humidifier)
terminal
on Thermidistat,
Zone
Controller
or
similar
device.
See Thermidistat'_,
Zone
Controller,
thermostat,
or controller
manufacturer's
instructions
for proper
connection.
VENTING
The furnace
shall be connected
to a listed factory
built chimney
or vent or a clay-tile
lined masonry
or concrete
chimney.
Venting
into
an
unlined
masonry
chimney
or concrete
chimney
is
prohibited.
When
an existing
Category
I furnace
is removed
or
replaced,
the original
venting
system
may no longer
be sized to
properly
vent
the
attached
appliances.
An
improperly
sized
Category
I venting
system
could
cause
the
formation
of
condensate
in the furnace
and vent,
leakage
of condensate
and
combustion
products,
and spillage
of combustion
products
into
the living space.
ACRDJ - AIR CONDITIONING
_
RELAY DISABLE JUMPER
r
=_
_oo
':O I V_)
I TEST/TWIN >
TRANSFORMER
24-VAC
CONNECTIONS
PL1 - LOW VOLTAGE MAIN
HARNESS CONNECTOR
PL3
CONNECTIONS
Bi"i°R
B, W R
:,b
Dr1I1
I HEAT
--
_
_
_
=
-_
(X LO HEAT, _j_
coo=_L_jt
1.AMpg_lSVAO
==IX
-
g=s
11_-VAC/u
tUNE
PLY- HOT SURFACE
BLOWER
SPEED_', S PARE-_ COOL\ VOLTAGE
CONNECTION
IGNITER
SINDUCER
SELECTION
_-_<ALS_
_
\
MOTOR
CONNECTOR
/EAC-_
TERMINAL
_
(115-VAC
1.0 AMP
MAX.)
A02017
Fig. 33 - Furnace
Control-PSC
Blower
Motor
25

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents