FURNACE
CASING
WIDTH
Table 4 - Opening
dimensions
- In. (mm)
APPLICATION
PLENUM OPENING
FLOOR OPENING
A
B
C
D
Upflow
Applications
on Combustible
or Noncombustible
Floor-
12-11/16
21-5/8
13-5/16
22-1/4
ing (KGASB
subbase
not required)
(322)
(549)
(338)
(565)
Downflow
Applications
on Noncombustible
Flooring
(KGASB
12-9/16
19
13-3/16
19-5/8
subbase
not required)
(819)
(483)
(335)
(498)
14-3/16
Downflow
applications
on combustible
flooring
(KGASB
sub-
11 - 18/16
19
18- 7/16
20-
5/8
(376)
base required)
(284)
(483)
(341)
(600)
Downflow
Applications
on Combustible
Flooring
with CNPV,
12-5/16
19
13-5/16
20
CNRV,
CAR, or CAP Coil Assembly
or KCAKC
coil box
(KGASB
subbase
not required)
(819)
(483)
(338)
(508)
Upflow
Applications
on Combustible
or Noncombustible
Floor-
16
21 -5/8
16-5/8
22-1/4
ing (KGASB
subbase
not required)
(406)
(549)
(422)
(565)
Downflow
Applications
on Noncombustible
Flooring
(KGASB
15-7/8
19
16-1/2
19-5/8
subbase
not required)
(403)
(483)
(419)
(498)
17-1/2
Downflow
applications
on combustible
flooring
(KGAS B su b-
15-1/8
19
16-3/4
20-5/8
(445)
base required)
(384)
(483)
(425)
(600)
Downflow
Applications
on Combustible
Flooring
with CNPV,
15-1/2
19
16-1/2
20
CNRV,
CAR, or CAP
Coil Assembly
or KCAKC
coil box
(KGASB
subbase
not required)
(394)
(483)
(419)
(508)
Upflow
Applications
on Combustible
or Noncombustible
Floor-
19-1/2
21-5/8
20-1/8
22-1/4
ing (KGASB
subbase
not required)
(495)
(549)
(511)
(565)
Downflow
Applications
on Noncombustible
Flooring
(KGASB
19-3/8
19
20
19-5/8
subbase
not required)
(492)
(483)
(508)
(498)
21
Downflow
applications
on combustible
flooring
(KGASB
sub-
18-5/8
19
20-1/4
20-5/8
(533)
base required)
(473)
(483)
(514)
(600)
Downflow
Applications
on Combustible
Flooring
with CNPV,
19
19
20
20
CNRV,
CAR, or CAP
Coil Assembly
or KCAKC
coil box
(KGASB
subbase
not required)
(483)
(483)
(508)
(508)
Upflow
Applications
on Combustible
or Noncombustible
Floor-
23
21 - 1/8
28-
5/8
22-1/4
ing (KGASB
subbase
not required)
(584)
(537)
(600)
(565)
Downflow
Applications
on Noncombustible
Flooring
(KGASB
22-7/8
19
28-1/2
19-5/8
subbase
not required)
(581)
(483)
(597)
(498)
24-1/2
Downflow
applications
on Combustible
flooring
(KGAS B su b-
22-1/8
19
28-
3/4
20-5/8
(622)
base required)
(562)
(483)
(603)
(600)
Downflow
Applications
on Combustible
Flooring
with CNPV,
22-1/2
19
28-1/2
20
CNRV,
CAR, or CAP
Coil Assembly
or KCAKC
coil box
(KGASB
subbase
not required)
(572)
(483)
(597)
(508)
U PFLOW
DOWN FLOW
HO REZO NTAL
YES
YES
[ ......
YES
\
120'_
MIN
/\
/\
YES
120°_
YES
120°_
YES
MIN
MIN
NO
NO
NO
Fig. 14 - Duct Flanges