Carrier 140/E Series Installation, Start--Up, Operating, And Service And Maintenance page 24

Table of Contents

Advertisement

DUAL
FUEL
TWO-STAGE
TWO-SPEED
TWO-STAGE
TWO-STAGE
TWO-SPEED
THERMOSTAT
FURNACE
HEAT
PUMP
THERMOSTAT
FURNACE
AIR
CONDITIONER
RVS COOLING
H EA(Tc/CMOpORL
SsTo#RG LEo 1)
HEA_FSTAGEE3
I_
HEAT/COOL
STAGE
2
(COMPRESSOR
HI)
FAN
24 VAC HOT
[_
24 VAC COMM
[_
N/A I_
RVS SENSING
I_
°S E s%R ........
CONNECT,ON
Ll q
__-"-O-T-E-
j_2___
-[_-
..............
-I q
-[_-
..............
-[_-
..............
HUM
OUTOOOR
SENSOR
_
I[
See notes
1, 2, 3, 4, 12, 13, 14, 15, and 17
on the page fo[Iowing these
figures
A03182
Fig.
30 - Dual
Fuel
Thermostat
with
Two-Stage
Furnace
and
Two-Speed
Heat
Pump
SINGLE-STAGE
TWO-STAGE
THERMOSTAT
FURNACE
E23-
EB-
EB-
NOTE 11
NOTE 12
-F¥7_
--
B HUM
See notes 2, 11, and 12 on the
page following
these figures
A03183
Fig.
31 - Two-Stage
Thermostat
with
Two-Stage
Furnace
and
Two-Speed
Air
Conditioner
TWO-SPEED
AIR CONDITIONER
-I_r
---
-I Jq
-I q
-I_r
---
-I_r
---
HUM
See notes 1 and 2 on the page
following these figures
Fig. 32 - Single-Stage
Thermostat
with Two-Stage
Furnace
and Two-Speed
Air Conditioner
A03184
FOR FIGURES
26-32
1. Heat pump MUST have a high pressure switch for dual fuel applications.
2. Refer to outdoor
equipment
Installation
Instructions
for additional
information
and setup procedure.
3. Outdoor Air Temperature
Sensor must be attached in all dual fuel applications.
4. Dip switch No. 1 on Thermidistat
should
be set in OFF position
for air conditioner
installations.
This is factory default.
5. Dip switch No. 1 on Thermidistat
should
be set in ON position for heat pump installations.
6. Dip switch No. 2 on Thermidistat
should
be set in OFF position
for single-speed
compressor
operation.
This is factory default.
7. Dip switch No. 2 on Thermidistat
should
be set in ON position for two-speed
compressor
operation.
8. Configuration
Option No, 10 "Dual Fuel Selection"
must be turned ON in all dual fuel applications.
9. NO connection
should
be made to the furnace
HUM terminal
when using a Thermidistat.
10. Optional connection:
If wire is connected,
dip switch SW1-2
on furnace control should
be set in ON position to allow Thermidistat/Thermostat
to control
furnace staging,
11. Optional connection:
If wire is connected,
ACRDJ jumper on furnace control should
be removed to allow Thermidistat/Thermostat
to control outdoor
unit
staging,
12. When using both a two-stage
furnace and a two-stage
heat pump, the furnace
must control its own high-stage
heating operation
via furnace control
algorithm.
13. The RVS Sensing
terminal
"L:' should not be connected.
This is internally
used to sense defrost operation.
14. DO NOT SELECT the "FURNACE INTERFACE"
or "BALANCE POINT" option on the two-speed
heat pump control board. This is controlled
internally by
the Thermidistat/Dual
Fuel Thermostat.
15. Dip switch D on Dual Fuel Thermostat
should
be set in OFF position for single-speed
compressor
operation.
This is factory default.
16. Dip switch D on Dual Fuel Thermostat
should
be set in ON position for two-speed
compressor
operation.
24