2.Adjust
the gas input
rate per the installation
instructions.
Low gas input rate causes low vent gas temperatures,
caus-
ing condensation
and corrosion in the furnace
and/or vent-
ing system.
Derating
is permitted
only for altitudes above
2000 fl
3. Adjust
the air temperature
rise to the midpoint
of the rise
range or slightly
above. Low air temperature
rise can cause
low vent gas temperature
and potential
for condensation
problems.
4. Set the thermostat
heat anticipator or cycle rate to reduce
short cycling.
Air
for
combustion
must
not
be
contaminated
by
halogen
compounds
which
include
chlorides,
fluorides,
bromides,
and
iodides.
These
compounds
are found
in many
common
home
products
such
as detergent,
paint,
glue,
aerosol
spray,
bleach,
cleaning
solvent,
salt, and air freshener,
and can cause corrosion
of furnaces
and vents.
Avoid
using
such
products
in
the
See Venting
Notes after Fig. 47.
combustion-air
supply.
Furnace
use during
construction
of the
building
could
cause
the
furnace
to be
exposed
to halogen
compounds,
causing
premature
failure
of the furnace
or venting
system
due to corrosion.
Vent dampers
on any appliance
connected
to the common
vent
can cause condensation
and corrosion
in the venting
system.
Do
not use vent
dampers
on appliances
common
vented
with
this
furnace.
ADDITIONAL
VENTING
REQUIREMENTS
A 4 in. (102 ram) round
vent elbow is supplied
with the furnace.
A 5 in. or 6 in. (127 or 152 ram) vent connector
may be required
for some model
furnaces.
A field-supplied
4 in. to 5 in. (102 to
127
ram) or 4 in. to 6 in. (102 mm to 152 ram) sheet
metal
increaser
fitting
is required
when
5 in. or 6 in. (127 or 152 ram)
vent connector
is used.
See Fig. 35-47
Venting
Orientation
for
approved vent configurations.
T o
o _
S "\
SEE NOTES: 1,2,4,7,8,9
on the page following
these figures
Fig. 35 - Upflow
Application-Vent
Elbow
Up
A03208
SEE NOTES: 1,2,3,4,7,8,9
on the pages following
these figures
Fig. 36 - Upflow
Application-Vent
Elbow
Right
A03209
29

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents