Platform
Furnace
Support
Construct
working
platform
at location
where all required
furnace
clearances
are met. (See Fig. 2 and 17.) For furnaces
with 1-in.
(25
ram)
clearance
requirement
on
side,
set
furnace
on
non-combustible
blocks,
bricks
or angle
iron.
For crawlspace
installations,
if the furnace
is not suspended
from the floor joists,
the ground
underneath
furnace
must be level and the furnace
set
on blocks
or bricks.
Roll- Out Protection
Provide
a n_ininmm
17-3/4-in.
x 22-in.
(451 x 559 ram) piece of
sheet metal
for flame roll-out
protection
in front of burner
area
for
furnaces
closer
than
12
inches
(305
ram)
above
the
combustible
deck
or suspended
furnaces
closer
than
12 inches
(305 ram) to joists.
The sheet metal MUST
extend underneath
the
furnace
casing by 1 in. (25 ram) with the door removed.
The bottom
closure
panel on furnaces
of widths
17-1/2
in. (445
ram) and larger may be used for flame roll-out
protection
when
bottom
of furnace
is used for return air connection.
See Fig.
17.
for proper
orientation
of roll-out
shield.
Bottom
Return
Air Inlet
These furnaces
are shipped
with bottom
closure panel installed
in
bottom
return-air
opening.
Remove
and discard
this panel when
bottom
return
air is used.
To remove
bottom
closure
panel,
perform
the following:
1. Tilt or raise furnace
and remove
2 screws
holding
bottom
filler panel. (See Fig.
9.)
2. Rotate
bottom
filler panel
downward
to release
holding
tabs.
3. Remove
bottom
closure
panel.
4. Reinstall
bottom
filler panel and screws.
Side Return
Air Inlet
These furnaces
are shipped
with bottom
closure
panel installed
in
bottom
return-air
opening.
This panel
MUST
be in place when
side return air inlet(s)
are used without
a bottom
return air inlet,
FURNACE
(OR COIL CASING
WHEN USED)
COMBUSTIBLE
FLOORING
SUBBASE
SHEET METAL
PLENUM
FLOOR
OPENING
A96285
Fig. 12 - Furnace,
Plenum,
and Subbase
installed
on a
Combustible
Floor
FURNACE
APPROVED
COIL ASSEMBLY
OR
COIL BOX
_
COMBUSTIBLE
FLOORING
"_
SHEET METAL
_
PLENUM
FLOOR
OPENING
/
Fig. 11 - Floor and Plenum
Opening
Dimensions
A96283
A08556
Fig. 13 - Furnace,
Plenum,
and Coil Assembly
or Coil Box
Installed
on a Combustible
Floor
12