Siemens SINAMICS G130 Engineering Manual page 213

Hide thumbs Also See for SINAMICS G130:
Table of Contents

Advertisement

Features
Control modes without
encoder
Setpoint resolution
speed/frequency
Setpoint resolution torque
Default sampling rate
Current/speed controller/
pulse frequency (Booksize)
Default sampling rate
Current/speed
controller/pulse frequency
(Chassis frame sizes FX and
GX)
Default sampling rate
Current/speed
controller/pulse frequency
(Chassis frame sizes HX
and JX and 690 V all frame
sizes)
Default output frequency
for current controller
cycle/pulse frequency
(Booksize)
Default output frequency
for current controller
cycle/pulse frequency
(Chassis frame sizes FX and
GX)
Default output frequency
for current controller
cycle/pulse frequency
(Chassis frame sizes HX
and JX)
Maximum field weakening
with asynchronous motors
Maximum field weakening
with synchronous motors
Servo control
Vector control
Speed control
Speed control/
Torque control
31 bits + sign
31 bits + sign
31 bits + sign
31 bits + sign
125 μs/ 125 μs/ 4 kHz
2 motor axes:
250 μs/ 1000 μs/ 4 kHz
4 motor axes:
400 μs/ 1600 μs/ 2.5 kHz
250 μs/ 250 μs/ 2 kHz
250 μs/ 1000 μs/ 2 kHz
400 μs/ 1600 μs/
1.25 kHz
650 Hz at 125 μs/
300 Hz at 250 μs/
4 kHz
4 kHz
300 Hz at 250 μs/
160 Hz at 250 μs/
2 kHz
2 kHz
100 Hz at 400 μs/
1.25 kHz
5 times
5 times
2 times
2 times
4 times with VPM,
see catalog PM21
Engineering Information
V/f Control
All V/f control modes
0.001 Hz
4 motor axes:
250 μs/ 4 kHz
6 motor axes:
400 μs/ 2.5 kHz
10 motor axes:
500 μs/ 4 kHz
4 motor axes:
250 μs/ 2 kHz
6 motor axes:
400 μs/ 1.25 kHz
10 motor axes:
500 μs/ 2 kHz
6 motor axes:
400 μs/ 1.25 kHz
400 Hz at 250 μs/
4 kHz
200 Hz at 250 μs/
2 kHz
100 Hz at 400 μs/
1.25 kHz
5 times
-
SINAMICS Engineering Manual - May 2008
© Siemens AG
SINAMICS S120
Notes
For asynchronous
motors only with Servo
With V/f control the
speed can be kept
constant by means of
selectable slip
compensation.
The sampling rate has
an important influence on
the dynamic control
response.
When "Isochronous
PROFIBUS" is selected,
the controller cycles are
automatically adjusted to
125 μs, 250 μs, 375 μs
and 500 μs.
Note limit voltage (2 kV)
and use of VPM Module
with synchronous
motors; see catalog
PM21.
With Servo control
combined with encoder
and appropriate special
motors, field weakening
up to 16 times the field-
weakening threshold
speed is poss ble.
These values refer to
synchronous motors of
type 1FK7/1FT6.
Please note the limit
voltage (kE factor) for
motors from external
suppliers.
213/396