Brief overview of SINAMICS G150 parallel converters with production date from autumn 2007

The following is a short overview of the permissible transformer-converter-motor combinations for SINAMICS G150
parallel converters.
6-pulse configuration
Line reactors required;
Symmetrical power
cabling
DC links of the parallel-
connected power units
are coupled
The outputs of the two
parallel-connected power
units are connected to a
motor with separate
winding systems.
Symmetrical power
cabling
Asynchronous motor with
two separate winding
systems
Control by SVM + PEM
Maximum motor voltage
related to the line voltage
97 %
Short overview about the configurations of SINAMICS G150 parallel converters with production date from autumn 2007
6-pulse configuration
Line reactors required;
Symmetrical power
cabling
DC links of the parallel-
connected power units
are coupled
The outputs of the two
parallel-connected power
units are connected to a
motor with one common
winding system.
Note specifications for
minimum motor cable
length or use motor
reactors in the converter.
Asynchronous motor with
one common winding
system.
Control by SVM
Maximum motor voltage
related to the line voltage
92 %
Engineering Information
12-pulse configuration
Decoupling by means of a
three-winding transformer.
Symmetrical power
cabling
DC links of the parallel-
connected power units
are coupled
The outputs of the two
parallel-connected power
units are connected to a
motor with separate
winding systems.
Symmetrical power
cabling
Asynchronous motor with
two separate winding
systems
Control by SVM + PEM
Maximum motor voltage
related to the line voltage
97 %
SINAMICS Engineering Manual - May 2008
SINAMICS G150
12-pulse configuration
Decoupling by means of a
three-winding transformer.
Symmetrical power
cabling
DC links of the parallel-
connected power units
are coupled
The outputs of the two
parallel-connected power
units are connected to a
motor with one common
winding system.
Note specifications for
minimum motor cable
length or use motor
reactors in the converter.
Asynchronous motor with
one common winding
system
Control by SVM
Maximum motor voltage
related to the line voltage
92 %