Error Conditions/Error Messages

Your spa has a self-diagnostic control system. The system will
automatically display the following if a problem is detected. Always
insist on genuine Jacuzzi replacement parts.
14.1

Panel Displays COOL

Cool Condition - Temperature has dropped 20°F (11°C)
below the current set temperature. The Jets Pump 1 and the
heater have been activated to bring the temperature within 15°F (8°C) of
the set temperature. No corrective action is required!
Note: This condition is common during first time fill ups or during refills
since tap water is often very cold.
14.2

Panel Displays ICE

Freeze Protection - A potential freeze condition has been
detected. No action is required. Water temperature is below
55°F (12.78°C). Jets Pump 1 and Jets Pump 2 will activate for 10 minutes,
then turn off. Then the Jets Pump 1 and the heater will activate for 10
minutes. The two cycles shall repeat until the water temperature reaches
65°F (18.33°C). See "Winterizing" (page 42).
14.3

Panel Displays SN--1

Open sensor (heater is disabled) or shorted sensor (spa is
deactivated). The high-limit temperature sensor is not
functioning. Contact your authorized Jacuzzi dealer or qualified service
technician. The display will alternate between "SN--1", scrolling
message "HI-LIMIT SENSOR ERROR" and the current water
temperature.
14.4

Panel Displays SN--2

Open or shorted sensor (heater disabled). The temperature
sensor is not functioning. Contact your authorized Jacuzzi
dealer or qualified service technician. The display will alternate between
"SN--2", scrolling message "WATER SENSOR ERROR" and the current
water temperature.
14.5

Panel Displays Change CLEARRAY Bulb

The CLEARRAY bulb timer has expired. UV bulb needs to be replaced.
The display will alternate between the current temperature reading and
the scrolling message "CHANGE CLEARRAY BULB" as long as the
error exists. The countdown timer for the UV bulb needs to be reset (page
33). A new UV bulb can be purchased from a local Jacuzzi dealer.