Preload Test Configuration; Typical Test Equipment - Intel Celeron D Thermal Design Manual

775-land lga package for embedded applications
Table of Contents

Advertisement

Heatsink Clip Load Metrology
Figure 18. Preload Test Configuration
B.5.8

Typical Test Equipment

For the heatsink clip load measurement, use test equipment equivalent to that listed in
Table 7.
Typical Test Equipment
Load cell
Notes: 1, 5
Data Logger (or scanner)
Notes: 2, 3, 4
NOTES:
1. Select load range depending on expected load level. It is best to operate in the high end of the load cell
capability if possible. Check with your load cell vendor for further information.
2. Since the load cells are calibrated in terms of mV/V, a data logger or scanner is required to supply 5 VDC
excitation and read the mV response. An automated model will take the sensitivity calibration of the load cells
and convert the mV output into pounds.
3. With the test equipment listed above, it is possible to automate data recording and control with a 6101-PCI
card (GPIB) added to the scanner, allowing it to be connected to a PC running LabVIEW* or StrainSmart*
software.
4. IMPORTANT: In addition to just a zeroing of the force reading at no applied load, it is important to calibrate
the load cells against known loads. Load cells tend to drift. Contact your load cell vendor for calibration tools
and procedure information.
5. When measuring loads under thermal stress (bake for example), load cell thermal capability must be
checked and the test setup must integrate any hardware used along with the load cell. For example, the
Model 13 load cells are temperature compensated up to 71°C as long as the compensation package (spliced
into the load cell's wiring) is also placed in the temperature chamber. The load cells can handle up to 121°C
(operating), but their uncertainty increases according to 0.02% rdg/°F.
Intel
44
Item
Honeywell*-Sensotec* Model 13 subminiature load cells,
compression only. Select a load range depending on
load level being tested.
www.sensotec.com
Vishay* Measurements Group Model 6100 scanner with
a 6010A strain card (one card required per channel).
®
®
Celeron
D Processor in the 775-Land LGA Package Thermal Design Guide
Preload Fixture (copper
core with milled out pocket)
Load Cells (3x)
Description
Table
7.
Part Number
AL322BL
Model 6100
Order #303730