Basic Settings; Disabling The Life Warning Display - Sony StorStation LIB-81 Operating Instructions Manual

Sony ait library operating instructions
Hide thumbs Also See for StorStation LIB-81:
Table of Contents

Advertisement

Basic Settings

Disabling the Life Warning Display

This section explains the steps required to configure the warning message
display, bar code, R-MIC and brightness of the LCD panel using the
Configuration Menu on the control panel.
Caution
There exist LIB-81 AIT library models without bar code or R-MIC readers.
Make sure that your library is equipped with a bar code and/or R-MIC reader
before modifying the "Barcode" or "R-MIC" setting. Modifying these settings
when using LIB-81 AIT library models that are not equipped with the
appropriate readers generates errors.
Note
For information about "Date & Time" of the Configuration Menu, refer to
"Setting the Date and Time" (page 22) in Chapter 2, "Installation".
When the device is shipped from the factory, the life warning is set to display.
This default setting is recommended. (Thus the following setup is unnecessary.)
Change this setting in "Warning" of the Configuration Menu.
Note
The displaying of the life warning can also be set through a browser.
1
At the status display, press the [MENU] button for two seconds.
2
Use the V and v buttons to select "5.Configuration", then press the
[ENTER] button.
3
Select "2.Warning", then press the
[ENTER] button.
4
Use the V and v buttons to select
"YES", then press the [ENTER]
button.
The default factory setting is
"YES".
Select "NO" to not display the warning.
5
When "[ENTER] to activate"
appears, press the [ENTER] button.
The life warning is now set.
The display returns to the menu.
6
Press the [CANCEL] button twice to return to the status display.
Configuration
1.Date & Time
2.Warning
3.Barcode
Warning
Enable
YES
Warning
Enable
YES
[ENTER] to activate
Chapter 3 Basic Usage