Advertisement

Figure 10: Components to Remove from the Rear of the Device
Cards in
Routing
CFM slots
Engine
Power
supplies
To remove the components from the device:
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and
1.
connect the strap to one of the ESD points on the chassis. For more information
about ESD, see the SRX 3400 Services Gateway Hardware Guide.
Release each component by loosening its retaining screws and unlatching its
2.
ejector handles as appropriate. For full instructions on removing device
components, see the SRX 3400 Services Gateway Hardware Guide.
Slide each component out of the chassis evenly so that it does not become stuck
3.
or damaged.
Label each component as you remove it so you can reinstall it in the correct
4.
location.
Immediately store each removed component in an antistatic bag.
5.
Do not stack removed components. Lay each one on a flat surface.
6.
NOTE: For complete instructions on removing device components, see Installing
the Services Gateway Without a Mechanical Lift" in the SRX 3400 Services Gateway
Hardware Guide.

Lift the Chassis into the Rack

Lifting the chassis and mounting it in a rack requires two people. The empty chassis
weighs approximately 32.3 lb (14.7 kg).
Ensure the rack is in its permanent location and is secured to the building.
1.
Position the chassis in front of the rack or cabinet. Use a pallet jack if one is
2.
available.
With one person on each side, lift the chassis into position in the rack:
3.
For two-post rack mounting, align the bottom hole in each mounting bracket
with a hole in each rack rail.
Fan tray
(behind door)
Step 3: Install the Device
Step 3: Install the Device
11