9.13 Panel unit
9.13.1 Panel unit
(1) Remove the four Taptite cup B M3x10 screws.
(2) Release each Hook to remove the Panel unit. Disconnect the Panel flat cable from the
Panel PCB ASSY.
Note:
• When removing the Panel unit, DO NOT pull the Panel unit strongly because it is
connected to the Panel flat cable.
Panel PCB ASSY
Panel flat cable
Taptite cup B M3x10
Harness routing: Refer to
Assembling Note:
• If you replaced the Panel unit, refer to
PANEL CONTROL PCB" in Chapter 4
(For Touch panel models)
Fig. 3-47
"3. Document scanner
Panel unit
Hooks
unit".
"4. IF YOU REPLACE THE PANEL UNIT OR
to configure settings.
3-55
Taptite cup B M3x10
Confidential