6.6.4.2.4
Reflective Sensor Manual Threshold Fine Adjustment (THRESHOLD<R>)
PAUSE
<Supplemental Explanations>
(1) When the [FEED] key is pressed, the menu moves in the opposite direction from when the
[PAUSE] key is pressed.
(2) When the [PAUSE] key is pressed while the [FEED] key is held down, or when the [POWER] key
is pressed for 3 seconds or more, the display returns to the system mode menu (ADJUST SET).
(3) When the [PAUSE] key or [FEED] key is pressed for 0.5 seconds or more during this fine
adjustment setting, repeat mode is enabled and the key pressed is repeatedly entered.
(4) The change in the fine adjustment value becomes effective when the [POWER] key is pressed
after setting, then stored in the backup memory.
(5) The factory default value is 1.0V.
(6) This setting is effective only in the TPCL and TPCL1 modes.
0.0V
0.1V
3.9V
4.0V
- 106 -