Adjustment Using The Temperature / Humidity Sensor; Adjustment Using The Drum Thermistor - Toshiba e-STUDIO350 Service Manual

Hide thumbs Also See for e-STUDIO350:
Table of Contents

Advertisement

12.4.3 Adjustment using the temperature / humidity sensor

Variation in the output (V
) of the auto-toner sensor due to humidity is corrected using the temperature
ATS
/ humidity sensor to maintain the toner density in the developer material at a certain amount.

12.4.4 Adjustment using the drum thermistor

Variation in the output (V
) of the auto-toner sensor due to temperature is corrected using the drum
ATS
thermistor to maintain the toner density in the developer material at a certain amount.
Feedback control by drum thermistor in setting mode (08)
Code
Item to be controlled
Default
08-840
Toner output control by drum thermistor
ON
12
November 2003 © TOSHIBA TEC
12 - 7
e-STUDIO350/450 DEVELOPMENT SYSTEM

Advertisement