GE CDT865SxJ0 Series Technical Service Manual page 45

2016 stainless steel tub dishwasher
Table of Contents

Advertisement

Top Control LCD Models
Fault
Code
F2
Communication Failed
F3
F5
Inverter Found On Incorrect MC
Personality
F6
Wireless Module (On some models)
F16
High Water Temperature
F33
Door Switch Error
F34
Leak Pan Detected Error
F36
CSM Tripped
F48
Turbidity Sensor High
F49
Turbidity Sensor Low
F50
Temperature Sensor High
F51
Temperature Sensor Low
F52
Turbidity Sensor Calibration Failure
F64
Inverter Error Received
F65
Inverter No Water Detected
F80
Absent Water Flow (turbidity based)
F96
No Water In Tub (turbidity based)
F97
Absent Heat Source
F98
Non-draining Sump (turbidity based)
F99
Minimum Wash Temp Not Met
F112
Key Stuck
F128
Low Rinse Aid
F144
Inverter Error Detected
F145
Inverter has detected incorrect AC
Voltage
F146
Circulation Pump Error
F147
Drain Pump Error
F148
Open TCO in circulation or drain motor
F149
Poor connection or harness to inverter
Description
– 45 –
Cause / Action or Check
User Interface control unable to communicate
with machine control
Inverter not detected on inverter equipped
model
correctly
Communication lost with wireless module
Check thermistor (replace as needed), replace
MB
Check door switch and wiring
Check for water leak in the
See On the Main Control Board CSM section of
this guide
Check turbidity sensor harness, replace sensor
Check turbidity sensor harness, replace sensor
Check thermistor and harness, replace MB
Check thermistor and harness, replace MB
Check turbidity sensor and harness
Check inverter and harness
Check inverter and harness
Check turbidity sensor harness, replace sensor
Check turbidity sensor harness, replace sensor
Check heater and thermistor
Check drain pump operation, turbidity sensor
harness, replace sensor
Check heater and thermistor
Check buttons, console and light pipe, replace UI
Fill rinse aid tank
Check harnessing, replace inverter
Check house voltage, harnessing, then replace
inverter if all is OK
Check harnessing, and replace the circulation
pump if needed
Check harnessing, replace drain pump if needed
Check connections and harness, replace inverter
if needed

Hide quick links: