Omron E5xK-T series Manual page 7

Digital
Table of Contents

Advertisement

E5AK-T/E5EK-T
Output Unit Ratings and Characteristics
Model
E53-R
Relay output
E53-S
SSR output
E53-Q
Voltage output
E53-Q3
E53-Q4
E53-C3
Linear current output
E53-C3D
E53-V34
Linear voltage output
E53-V35
Note: An output relay (1 A at 250 VAC) is mounted on the position-proportional model. (When replacing, use the E53-R.)
Option Unit Ratings and Characteristics
Model
E53-AKB
Event input
Co
Communications
u ca o s
E53-AK01
E53-AK02
E53-AK03
E53-AKF
Transfer output
Note: Event input is used for switching the target value, run or stop command, or automatic and manual mode with an external signal input.
Current Transformer Ratings
Dielectric strength
Vibration resistance
Weight
Accessories (E54-CT3 only)
Heater Burnout Alarm
Max. heater current
Heater current value display accuracy
Heater burnout alarm setting range
Min. detection ON time
Note: 1. Use the K2CU-F
2. The heater burnout alarm is always OFF if the alarm is set to 0.0 A and always ON if the alarm is set to 50.0 A.
3. No heater burnout detection or heater current value measurement is possible if the control output (heat) is ON for less than 190 ms.
5 A at 250 VAC (resistive load)
1 A at 75 to 250 VAC (resistive load)
NPN: 40 mA at 12 VDC
NPN: 20 mA at 24 VDC
PNP: 20 mA at 24 VDC
4 to 20 mA, permissible load impedance: 600 Ω max., resolution: approx. 2,600
0 to 20 mA, permissible load impedance: 600 Ω max., resolution: approx. 2,600
0 to 10 VDC, permissible load impedance: 1 kΩ min., resolution: approx. 2,600
0 to 5 VDC, permissible load impedance: 1 kΩ min., resolution: approx. 2,600
Contact input:
ON: 1 kΩ max., OFF: 100 kΩ min.
No-contact input:
ON: residual voltage 1.5 V max., OFF: leakage current 0.1 mA max.
Transmission method:
a s
RS-232C
Synchronization method: Start-stop synchronization (asynchronous method)
S
h
RS-422
Baud rate:
Baud rate:
RS-485
4 to 20 mA:
Permissible load impedance: 600 Ω max.
Resolution: approx. 2,600
1,000 VAC (for 1 min)
2
50 Hz, 98 m/s
(10G)
E54-CT1: approx. 11.5 g; E54-CT3: approx. 50 g
Armature: 2; Plug: 2
Single-phase 50 A VAC (see note 1)
5% FS 1 digit max.
0.1 to 49.9 A (in units of 0.1 A) (see note 2)
190 ms (see note 3)
A- GS (with gate input terminals) for the detection of three-phase heater burnout.
Specifications
(with short-circuit protection)
(with short-circuit protection)
(with short-circuit protection)
Specifications
ss o
e od
Half-duplex
a du e
i
ti
th d St t t
1.2/2.4/4.8/9.6/19.2 kbps
1 2/2 4/4 8/9 6/19 2 kbps
E5AK-T/E5EK-T
h
i
ti
(
h
th d)
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

E5ak-tE5ek-tE5ck-t

Table of Contents