Omron E5xK-T series Manual page 2

Digital
Table of Contents

Advertisement

E5 K-T
Compact and Easy-to-use Controllers
Programming is as easy as following the steps below.
Program can be set in pattern 0 according to the following proce-
dure.
SP
Step 1
Step 2
100
50
0.20
Step No.
Target value
0
50
1
100
2
100
3
50
1. Press the Display Key to shift to the display
for the number of steps.
5 no
0
8
2. Press the Down Key and set the number of
steps.
5 no
0
4
3. Press the Display Key to shift to the display
for the target value of step 0.
5p0
0
0
2
Step 3
0.40
0.20
Time: hours and minutes
Time
(hours.minutes)
0.00
0.20
0.40
0.20
Parameter for the number of
steps used
Number of steps
(Default setting: 8)
Pattern No.
Display key
Four steps in this case
Down key
Step 0
Parameter of the target value
Target value
(Default setting: 0)
Display key
4. Set the target value to "50."
5p0
0
50
5. Press the Display Key to shift to the display
for the time of step 0.
ti0
0 000
6. Press the Display Key again with the step
time set at 0 minutes, and the target value
parameter for step 1 will be displayed.
5p1
0
0
7. Press the Up Key to increment to "100."
5p1
0 100
In the same manner, set the time for step 1, tar-
get value for step 2, time for step 2, etc.
When the target value and time settings are
complete, press the Display Key.
E5 K-T
Target value
Up key
Time parameter for step 0.
Step time
(Default setting: 0.00)
Pattern No.
Display key
Display key
Up key