Cause
MDB slave error detected
Slow coffee boiler warm-up
Credit Manager warning
Watchdog operation
MDB coin return error
message
Consumed softener filter signal
I stop funds intervened
Boiler filling procedure
not completed
successfully
Sensor type incorrect
(probably a wrong VM
model has been selected)
Flowmeter pulses not
detected during loader
steam cycle
Steam boiler sensor error
Both boilers out of service
Slow steam boiler warm-up
Coffee boiler filling failed
No dreg drawer detected
Error Code
Effect
35
Warning only
36
Vending machine out of service
42
Warning only
72
Warning only
80
Warning only
83
Warning only
84
Coffee products disabled
85
Blocked V. M.
87
Blocked V. M.
88
Steam stop
Beverages with steam not
92
available
93
Blocked V. M.
94
95
Coffee beverages not available
"Insert coffee grounds
98
drawer" message displayed
Notes / Recommended Intervention
Warning report only in the LOG.
Check the coffee boiler (connections, thermostats)
The credit management system has
overcome a possible blocking condition
(credit watch-dog enabling).
Warning report only in the LOG.
Warning report only in the LOG.
Check the coin return.
Maintain the softener filter
Remove and empty the coffee grounds drawer
Repeat automatic filling (turn the vending machine off
and on again)
Check water circuit
Select the correct vending machine model
(System Management Menu)
Check connections of temperature
sensors
Check flowmeter, water pump and steam
solenoid valve operation.
Check the steam boiler (connections, thermostats,
temperature sensor).
Check boilers (connections, thermostats,
temperature sensor)
Check the steam boiler (connections, thermostats,
temperature sensor).
Check the water circuit (pump, flowmeter).
Warning report only in the LOG.
Insert coffee grounds drawer.