Preparation for Operation
Modified bootcfg program output
Boot Loader Settings
----------------------------
timeout: 30
default: multi(0)disk(0)rdisk(0)partition(1)\WINDOWS
redirect: COM1
redirectbaudrate: 19200
Boot Entries
----------------
Boot entry ID: 1
OS Friendly Name: Windows Server 2003, Standard
Path: multi(0)disk(0)rdisk(0)partition(1)\WINDOWS
OS Load Options: /fastdetect /redirect
You must restart the Windows 2003 operating system after completing this
procedure for the changes to take effect and to enable SOL.
Installing the OSA SMBridge management utility program
Complete the following steps to install the OSA SMBridge management utility
program on a server running a Windows operating system:
Ê Go to http://www.fujitsu-siemens.com/support/, download the utility
program, and create the OSA BMC Management Utility CD.
Ê Insert the OSA BMC Management Utility CD into the drive.
Alternatively, you can use the ServerStart CD.
i
The InstallShield wizard starts.
Ê Follow the prompts to complete the installation. The installation program
prompts you for a TCP/IP port number and an IP address. Specify an IP
address, if you want to limit the connection requests that will be accepted by
the utility program. To accept connections from any server, type
INADDR_ANY as the IP address. Also specify the port number that the utility
program will use. These values will be recorded in the smbridge.cfg file for
the automatic startup of the utility program.
To install the OSA SMBridge management utility program on a server running a
Linux operating system, complete the following steps. You must be logged in as
a root user to perform these procedures:
Ê Go to http://www.fujitsu-siemens.com/support/, download the utility
program, and create the OSA BMC Management Utility CD.