No Monitor Display Or Display Drifts; Time And/Or Date Are Incorrect; System Fails To Boot; Drives "Dead" At System Boot - Fujitsu PRIMERGY RX800 S2 Operating Manual

Hide thumbs Also See for PRIMERGY RX800 S2:
Table of Contents

Advertisement

Miscellaneous Problems
5.2.5

No Monitor Display or Display Drifts

The wrong horizontal frequency and/or resolution has been selected for
the monitor or for the application program.
Ê Find out which horizontal frequency your monitor supports. You will find the
horizontal frequency (also known as line frequency or horizontal deflection
frequency) in the documentation for your monitor.
Ê Refer to the documentation for your operating system or to the corre-
sponding software for the monitor controller for how to set the correct
horizontal frequency for your monitor, and follow the procedure accordingly.
5.2.6

Time and/or Date are Incorrect

Ê Set the time and/or date in the operating system or in the BIOS Setup Main
menu.
I
If the time and date are repeatedly wrong when you switch on your
server, you must change the lithium battery (see Service Manual), or
contact our Service organization.
5.2.7

System Fails to Boot

The system fails to boot after installing a new hard disk drive.
SCSI configuration incorrect
Ê Check the settings for the hard disk drives in the SCSI configuration menu.
5.2.8

Drives "dead" at System Boot

RAID controller configuration incorrect
Ê Check and correct the settings for the drives with the RAID controller utility.
Further information is provided in the manual on the RAID controller.