Siemens SIMOTICS S-1FK7 DYA Generation 2 Operating Instructions Manual page 60

Synchronous motors with planetary gearbox
Table of Contents

Advertisement

Connecting
6.4 System integration
Current-carrying capacity for power and signal cables
The current-carrying capacity of PVC/PUR-insulated copper cables is specified for routing
types B1, B2 and C under continuous operating conditions in the table with reference to an
ambient air temperature of 40° C. For other ambient temperatures, the values must be
corrected by the factors from the "Derating factors" table.
Cable cross-section and current-carrying capacity
Cable cross-section and current-carrying capacity
Derating factors for power and signal cables
Derating factors for power and signal cables
58
Cross-section
mm
2
0.20
0.50
0.75
0.75
1.00
1.50
2.50
4
6
10
16
25
35
50
Ambient air temperature [°C]
30
35
40
45
50
55
60
Current-carrying capacity rms; AC 50/60 Hz or DC for routing type
B1
/ A
Electronics (according to EN 60204-1)
-
-
-
Power (according to EN 60204-1)
8.6
10.3
13.5
18.3
24
31
44
59
77
96
117
Derating factor according to EN 60204-1, Table D1
S-1FK7 DYA G2 synchronous motors with planetary gearbox
Operating Instructions, 05/2018, A5E44881183B AA
B
2 / A
4.3
7.5
9
8.5
10.1
13.1
17.4
23
30
40
54
70
86
103
1.15
1.08
1.00
0.91
0.82
0.71
0.58
C
/ A
4.4
7.5
9.5
9.8
11.7
15.2
21
28
36
50
66
84
104
125