System Integration; Connection Notes - Siemens SIMOTICS S-1FK7 DYA Generation 2 Operating Instructions Manual

Synchronous motors with planetary gearbox
Table of Contents

Advertisement

6.4

System integration

6.4.1

Connection notes

NOTICE
Destruction of the motor if it is directly connected to the three-phase line supply
The motor will be destroyed if it is directly connected to the three-phase line supply.
• Only operate the motors with the appropriately configured converters.
NOTICE
Damage to electronic components as a result of electrostatic discharge
Electrostatically sensitive devices (ESD) can be damaged or destroyed by electrostatic
discharge.
• Observe the ESD protection measures.
• Only grounded personnel with grounded tools may touch the component connections.
• Heed the EMC information provided by the manufacturer of the converter.
● Use prefabricated cables from SIEMENS (not in the scope of delivery). These cables
reduce installation costs and increase operational reliability (see the Product Information).
● The manufacturer of the plant/machine is responsible for ensuring that installation is
performed correctly.
● Observe the data provided on the rating plate and the circuit diagrams.
● Adapt the connection cables to the type of use and the voltages and currents that occur.
● When fed from a converter, high-frequency current and voltage oscillations in the motor
feeder cables can cause electromagnetic interference. Therefore, use shielded power
cables.
● Make sure that the inside of the connector is clean and free of cable cuttings and
moisture.
● Avoid protruding wire ends.
● Check that the degree of protection is complied with at the seals and sealing surfaces of
the connectors.
● Secure connecting cables against torsion, tensile and compressive strain, and protect
them against kinking. It is not permissible to subject the connector to continuous force.
● Insert the coding groove of the plug-in connection into the socket until flush and tighten
the screw cap by hand in as far as it will go.
S-1FK7 DYA G2 synchronous motors with planetary gearbox
Operating Instructions, 05/2018, A5E44881183B AA
Connecting
6.4 System integration
57

Advertisement

Table of Contents
loading

Table of Contents