Tightening torques for fastening bolts
Motor
1PV513x/
DE
1FV513x
NDE
DE
1FV516x
NDE
The mounting tools to be used are a torque wrench or pneumatic or impact power
screwdriver with automatic switch-off.
5.4

Mounting conditions

Note
To ensure enough heat is dissipated, a minimum clearance to adjacent components of 100
mm must be kept free on three side surfaces.
● Mount the motor in such a way that sufficient clearance is provided for heat dissipation.
The motor ratings apply in an ambient temperature of 40° C (104° F). If the ambient
temperature exceeds 40° C (104° F), you must adjust the torque and power of the motor
accordingly.
● Determine the permissible motor torque using the formula provided in Chapter "Derating
factors (Page 28)".
Follow the Operating Instructions of the converter.
S-1FK7 DYA G2 synchronous motors with planetary gearbox
Operating Instructions, 05/2018, A5E44881183B AA
Screw
M 12
M12 (screw-in depth, 25...30 mm)
M 16
M12 (screw-in depth, 18...20 mm)
5.4 Mounting conditions
Tightening torque
Property class of the
±10 % [Nm]
85
85
190
85
Mounting
screws
8.8
8.8
10.9
8.8
51