6.5.4. System type
Select the system in which the valve(s) operate(s).
Options:
•
4: single valve;
•
5: multiple valve with lockout;
•
6: multiple valve with consecutive regenerations;
•
7: duplex alternating;
•
9: multiple valve, alternating;
•
14: multiple demand valves.
D
Set the system type with
E
Press
to validate the selection and advance to the next
parameter.
6.5.5. Valve address in the system
Set the valve position in the system.
Note
Only visible in systems 5, 6, 7, 9 and 14.
Note
The number #1 is the lead valve (master) and contains the programmed parameters used
by the other controllers in the system in order to control the regeneration and service or
standby positions.
Options:
•
address #1: valve 1, lead (master);
•
address #2: valve 2;
•
address #3: valve 3;
•
address #4: valve 4.
F
Set the valve position with
→ Default setting: valve 2 address #2.
G
Press
to validate the selection and advance to the next
parameter.