6.5.12. System capacity

Set the capacity of the tank where the valve is installed.
Note
On the basis of system capacity, safety coefficient and inlet water hardness, the controller
calculates the volume of water that the system can treat between 2 regenerations.
T
Set the unit capacity with
U
Press
to validate the selection and advance to the next
parameter.
This volume corresponds to the volume the tank could treat if the inlet water hardness is 1°F, 1°TH
or 1°dH.

6.5.13. Safety coefficient

Set the percentage value by which the total capacity is reduced as a safety coefficient.
V
Set the safety coefficient with
→ Can be adjusted from 0 to 50%.
W Press
to validate the selection and advance to the next
parameter.

6.5.14. Inlet water hardness

Set the input water hardness in the unit set on chapter 6.5.11. Display format, page 64.
X
Set the safety coefficient with
Y
Press
to validate the selection and advance to the next
parameter.

6.5.15. Trip points setting

Set the flow rate and switching delay when another tank is switched to service.
Note
Only visible in system 14.
Ref. MKT-IM-010 / B - 28.05.2018
Installer Manual Fleck 3150 - NXT - Programming
,
and
.
,
and
.
,
and
.
Example: 3000 g of CaCO
capacity
UNIT CAPACITY:
003000 gCaCO3
No safety factor programmed
CAPACITY SAFETY 
FACTOR
00%
FEED WATER
HARDNESS:0030mgL
of
3
65 / 122