• In some applications local municipalities treat water with Chloramines. High Chloramine levels may damage valve components. • Correct and constant voltage must be supplied to the controller to maintain proper function. 2 • PENTAIR® FLECK® 5000 Control Valve Service Manual...
Hot Water Grounding Soft Water Outlet Strap Hard Water Bypass Drain Line Water Heater Brine Tank Over ow Drain (Optional) Laundry Tubs Pump Meter Softener Floor Drain Figure 1 Softened Water Flow • 3 PENTAIR FLECK 5000 Control Valve Service Manual...
The salt tank should have water in it to permit the chlorine solution to be carried into the softener. B. Proceed with the normal recharge. 4 • PENTAIR FLECK 5000 Control Valve Service Manual...
5. Lubricate the distributor o-ring seal and tank o-ring seal. Place the main control valve on tank. NOTE: Only use silicone lubricant. • 5 PENTAIR FLECK 5000 Control Valve Service Manual...
3. When the desired time is set, press the Extra Cycle button to resume normal operation. The unit will also return to normal operation after 5 seconds if no buttons are pressed. 6 • PENTAIR FLECK 5000 Control Valve Service Manual...
Page 7
Pressing the Extra Cycle button during a regeneration cycle immediately advances the valve to the next cycle step position and resumes normal step timing. • 7 PENTAIR FLECK 5000 Control Valve Service Manual...
NOTE: Some items may not be shown depending on timer configuration. The timer will discard any changes and exit Master Programming Mode if any button is not pressed for sixty seconds. 8 • PENTAIR FLECK 5000 Control Valve Service Manual...
Page 9
Tanks in your system. This option setting is identified by Liters 24-Hour “NT” in the upper left hand corner of the screen. There are two possible settings: Cubic Meters 24-Hour Single Tank System: 1 Two-Tank System: 2 • 9 PENTAIR FLECK 5000 Control Valve Service Manual...
Page 10
There are two possible settings. in the upper left hand corner of the screen. Use the Up and Down buttons to adjust the value as needed. Safety Factor Fixed Reserve Capacity 10 • PENTAIR FLECK 5000 Control Valve Service Manual...
Page 11
Day of Week controls. This setting is identified by “CD” in the upper left-hand corner of the screen. Use the Up and Down buttons to select from Day 1 through Day 7. • 11 PENTAIR FLECK 5000 Control Valve Service Manual...
Range: 4-199 hardness 5. Press the Extra Cycle button. Use this display to adjust the Fixed Reserve Capacity. This option setting is identified by “RC” in the upper left-hand Corner of the screen. 12 • PENTAIR FLECK 5000 Control Valve Service Manual...
5. Press the Up button. Use this display to view the Volume Used since the last regeneration cycle. This option setting is identified by “VU” in the upper left hand corner of the screen. • 13 PENTAIR FLECK 5000 Control Valve Service Manual...
Power Supply, #1 Injector, 0.50 GPM BLFC ..500006-003 ..Turbine Meter, B/W Filter, U.S. Power Supply NOTE: NOTE: Above part numbers DO NOT include the following parts. Bypass Assembly Connector Assembly Flow Washer DLFC 14 • PENTAIR FLECK 5000 Control Valve Service Manual...
Page 15
COMPONENTS / ASSEMBLIES TO BE COMPLIANT AND COMPATIBLE WITH EUROPEAN UNION DIRECTIVE 2011/65/EEC (RoHS2) & REGULATION (EC)1907/2006 (REACH) REQUIRE ����������19152 ��������������������� Washer, Flow, 0�8 GPM THIS DOCUMENT IS SOLELY THE PROPERTY OF PENTAIR THIRD ANGLE 4 ������������������� 1 ����������18277 ��������������������� Cap Injector RESIDENTIAL FILTRATION, LLC.
Hard water enters unit at valve inlet - flows around piston - down center tube - through bottom distributor and up through the mineral - around the piston and out the drain line. 22 • PENTAIR FLECK 5000 Control Valve Service Manual...
Page 23
Rapid Rinse Position Hard water flows from inlet around the piston down through the mineral into bottom distributor and up through center tube - through piston and out through the drain line. • 23 PENTAIR FLECK 5000 Control Valve Service Manual...