Resin Exchange Capacity And Capacity Of The Unit - Pentair FLECK 3150 NXT Installer Manual

Hide thumbs Also See for FLECK 3150 NXT:
Table of Contents

Advertisement

Installer Manual Fleck 3150 - NXT - System sizing
The maximum softened water flow rate that a softener can produce is given by the following formula:
Q
= Fs
service max
service
Knowing this required volume of resin, it is possible now to determine the tank you need. Note that at
least a third of the total volume of the tank must be kept as free space so that the bed expansion
during backwash is sufficient to ensure correct cleaning of the resin.

4.2.3. Resin exchange capacity and capacity of the unit

The resin exchange capacity and capacity of the unit are two different things that should not be
confused. The resin exchange capacity is the amount of Ca
of resin, which will depend on the resin type and salt dosage, whereas the capacity of the unit is the
capacity of the system, which will depend on the volume of resin and resin exchange capacity.
Knowing the required volume of resin, you can determine the exchange capacity of the unit. The
capacity of the unit can be expressed in different ways:
the mass capacity, which corresponds to the weight in equivalent CaCO
resin, expressed in kg as CaCO
the volume capacity, which represents the maximum amount of water that can be treated
between 2 regenerations. This last capacity takes into account the hardness of the water to be
treated and is expressed in m
the combined capacity, which represents the volume of water that could be treated between 2
regenerations if the inlet hardness is 1 °f or °dH. This capacity is expressed in °f.m
The resin exchange capacity will depend on the amount of salt to be injected into the resin bed during
the regeneration. This amount of salt is given in grams per litre of resin. The next table is showing the
resin exchange capacity in function of the amount of salt for a system with standard efficiency
regeneration.
Resin exchange capacity as a function of the salt dosage:
Salt amount
[g/L
]
resin
50
60
70
80
90
100
26 / 122
x BV
;
3
3
or litres;
Corresponding resin exchange
capacity in [g/L
resin
29.9
34
37.5
40.6
43.4
45.9
with:
Q
: service flow rate [m
service max
Fs
: service velocity [BV/h]
service
BV: bed volume of resin [m
2+
2+
and Mg
°f.m
] as CaCO
[per L
3
2.99
3.4
3.75
4.06
4.34
4.59
Ref. MKT-IM-010 / B - 28.05.2018
3
/h]
3
]
that can be retained by 1 litre
that can be fixed on the
3
3
or °dH.m
3
°dH.m
]
[per L
resin
resin
1.67
1.9
2.09
2.27
2.42
2.56
3
.
3
]

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents