3 Controlling Operation and Data Output with Ethernet
Category
Confirm
Firmware
Version
Save for
Power-on,
Re-initialize
and Restart
Master Data-
base
3 - 44
Command
<#>
Queries all the firmware version information.
<#a>
Queries the version information of application
software.
<#b>
Queries the Boot Software Version
information.
<#w>
Queries the WebLink version.
<!>
Queries the Application software checksum
and Boot Software checksum.
<!a>
Queries the Application software checksum.
<!b>
Queries the Boot Software checksum.
<Z>
Saves current settings to the reader and re-
starts it.
<Zc>
Saves the current setting as the Customer
default setting on the reader and restarts.
<Zrc>
Restores the reader settings to the customer
default and restarts the reader.
<Zrd>
Resets the reader to its factory default settings
(excluding communication settings and user-
defined names) and restarts.
<Zrdall>
Resets the reader to its factory default settings
and restarts.
<A>
Restarts the reader with its current settings.
<Ard>
Resets the reader to its factory default settings
(excluding communication settings and user-
defined names) and restarts.
<Arp>
Restores the reader settings to the previously
saved state and restarts.
<Arc>
Restores the reader settings to the customer
default and restarts.
<G>
Sets the database number to be registered in
the Master database to 1.
<Gn>
Sets the database number to be registered in
n: Master
the Master database to n.
Database
Index
Number
<NEWM>
Queries the database number to register.
<NEWM/00> is returned if there is no
database yet specified to be registered.
V430-F Series Auto Focus Multi Code Reader User Manual for Communication Settings (Z407-E1)
Description
Response Data Example
(For Read string ABCDE.)
<#b/
35-9000033-122.3021><#a/
35-9000097-1.2.3.3008><#w/
30-9000079-1.2.3.3006><#p/
N/A><#d/35-xxxxxx-
x.x.x.xxxx>
<#a/35-9000097-1.2.3.3008>
<#b/35-9000033-122.3021>
<#w/30-9000079-1.2.3.3006>
<!b/38B7><!a/9555>
<!a/9555>
<!b/38B7>
<A?/0>
<A?/0>
<A?/0>
<A?/0>
<A?/0>1>
<A?/0>
<A?/0>
<A?/0>
<A?/0>
None
<NEWM/01>
(The data for the next Good
Read is registered in Master
database 1.)
None