Omron V430-F Series User Manual For Communication Settings page 81

Code reader, auto focus multi code reader
Hide thumbs Also See for V430-F Series:
Table of Contents

Advertisement

 Additional Symbol Information that can be Appended
Additional
Information
Symbol
Identifier
Decodes per
Trigger
Configuration
Data
Identifier
Frame
Number
Code
Position
Coordinates
Symbol Qual-
ity (ISO/IEC
16022)
Symbol
Quality
(Omron
Microscan)
Symbol Qual-
ity (ISO/IEC
15415)
Symbol Qual-
ity (ISO/IEC
15416)
Symbol Qual-
ity (ISO/IEC
29158)
Read Time
Read Cycle
ID
*1.
For more information on Symbol Quality grading, please refer to Symbol Quality in Auto Focus Multi
Code Reader V430-F Series User Manual (Z392).
V430-F Series Auto Focus Multi Code Reader User Manual for Communication Settings (Z407-E1)
3 Controlling Operation and Data Output with Ethernet
Setting to Adjust
(WebLink -
Advanced
Settings Menu)
I/O - Symbol Data
A (3 character) Symbol Identifier
Output
indicating the type of the read
symbol is put in front of its Read
string.
I/O - Decodes per
Outputs the number of Good Read
Trigger Output
in Read Cycle.
I/O - Database
Outputs the Index Number of the
Identifier Output
Configuration Database used to get
a Good Read.
I/O - Output Object
Outputs the Frames number
Info
(number of images) that were
needed to get a Good Read result.
The output is a 3 digit number.
I/O - Output Object
Outputs the coordinates of the four
Info
vertices of the read symbol in
pixels.
Symbol Quality -
Outputs the DataMatrix Symbol
ISO/IEC 16022
Quality grade defined by ISO/IEC
Parameters
16022.
Symbol Quality -
Outputs the Omron Microscan
Omron Microscan
Proprietary Symbol Quality grade.
Parameters
Symbol Quality -
Outputs the Symbol Quality grade
ISO/IEC 15415
defined by ISO/IEC 15415 for 2D
Parameters
Codes.
Symbol Quality -
Outputs the Symbol Quality grade
ISO/IEC 15416
defined by ISO/IEC 15416 for Bar-
Parameters
code symbols.
Symbol Quality -
Outputs the Symbol Quality grade
ISO/IEC 29158
defined by ISO/IEC TR 29158 for
Parameters
2D Codes.
I/O - Read
Outputs the Read Duration time in
Duration Output
milliseconds.
I/O - Output Cycle
The Output Cycle ID number
ID
(number of Reads executed) is
output in hexadecimal format.
Description
*1
*1
*1
*1
*1
Example Output
(For Read string
ABCDE. The
Output
delimiter
Order
character is a ,
<comma>.)
]dlABCDE
Put in
front of
the Read
string
ABCDE,00002
1
ABCDE,DB01
2
ABCDE,F010
3
ABCDE,
4
(0032,0040)
(0287,0056)
(0287,0279)
(0048,0271)
ABCDE,B,A,A,A
5
ABCDE,000,092,14
6
3,091,001,14.3,200,
16X16,PASS,349
ABCDE,C,A,C,C,C,
7
A,A,A
ABCDE,C,A,A,A,A,
8
A,C,A,A,A
ABCDE,C,C,A,B,C,
9
A,A,A
ABCDE,100
10
ABCDE,CycleID=0x
11
8
3 - 37
3

Hide quick links:

Advertisement

Table of Contents
loading