32 bit
Output Control Echo
Out1 Echo
Out2 Echo
Out3 Echo
Reserved
32 bit
Read Cycle Sequence count DINT
32 bit
Decode Data Length
Decode Data
Large Input Assembly (Instance ID: 101)
Compared to the Small Input Assembly, the Large Input Assembly holds more Device Status
information and Read result character strings of 128 bytes. When reading multiple symbols, the Read
strings are output delimited by Separator Characters.
Large Input Assembly Member Structure
USER-DEFINED TAG ECHO
COMMAND ECHO
OUTPUT CONTROL ECHO
EXTERNAL INPUT STATUS
EXTERNAL OUTPUT STATUS
DEVICE STATUS
READ CYCLE SEQUENCE COUNTER
TRIGGER COUNT
DECODE/MATCH COUNT
MISMATCH COUNT
NOREAD COUNT
DECODE DATA LENGTH
DECODE DATA STRING
Member Description
• Output Control Echo
Returns the value set in the External Output field of the Output Assembly (Legacy).
• External Input Status
Indicates the current state of the Parallel Input signal.
0
1
2 - 31
Numeric value in Bit
0 = OFF
1 = ON
• External Output Status
Indicates the current state of the Parallel Output signal.
V430-F Series Auto Focus Multi Code Reader User Manual for Communication Settings (Z407-E1)
Member Name
Member Name
Bit
Trigger
New Master
Reserved
Data Type
Bit Number
DINT
0
1
2
3 - 31
0 - 31
DINT
0 - 31
SINT[64]
0 - 512
4
4
4
4
4
4
4
4
4
4
4
4
128
Signal Name
Appendices
Data Length
Byte Offset
4 Byte
8
1 bit
1 bit
1 bit
29 bit
4 byte
12
4 byte
16
64 byte
20
Size (Bytes)
Total Size: 176 Bytes