Output Assembly (Legacy) Member Structure
USER DEFINED TAGS
COMMANDS
EXTERNAL OUTPUT
Member Description
• User Defined Tags
Data set for this Member is echoed back to the USER-DEFINED TAG ECHO area of the Small Input
Assembly or the Large Input Assembly. It is used when you want to uniquely identify multiple read-
ers.
• Commands
An explanation of commands that can be sent to the reader.
Bit
0
1
2 - 7
8
9 - 15
16
17
18 - 31
・Trigger
Executes Read. The reader recognizes this bit changing from 0 to 1 as the rising edge of the trigger
and its change from 1 to 0 as the falling edge of the trigger.
・New Master
When this bit is ON, the next Read result is registered as the Master Symbol.
・Disable Scanning
Enables / Disables Read Cycle.
0 = Read Cycle Enabled.
1 = Read Cycle Disabled. However, other commands can be executed.
・Clear Read Cycle Report and Counters
Reset the Counter area from the Small or Big Input Assembly to the Read character string area to 0.
・Unlatch Outputs
Turns OFF Parallel OUTPUT1, OUTPUT2, OUTPUT3 signals.
・External Ouput: External Output
Turns ON Parallel OUTPUT Signal.
Bit
0
1
2
3 - 31
V430-F Series Auto Focus Multi Code Reader User Manual for Communication Settings (Z407-E1)
Member Name
Trigger
New Master
Reserved
Disable Scanning
Reserved
Clear Read Cycle
Unlatch Outputs
Reserved
Output 1
Output 2
Output 3
Reserved
Size (Bytes)
4
4
4
Total Size: 12 Bytes