1. Output1
Match
(or Good Read)
Use as Ext. Illumination Strobe - (Output 3 Signal Only)
Outputs the signal used to illuminate with external lighting.
The illumination time length is dependent on the setting for Fixed Light On Time and its timing is
dependent on the setting for Fixed Light Delay Time.
The setting selected for Output Mode is disabled.
• WebLink - Setup - Gear Icon - Advanced Settings - Camera Setup - Lighting
Setting Item
Light Source
Fixed Light On Time
Fixed Light Delay
Time
Below is an Output assignment example and Timing chart.
[Example assignment of OUTPUT signals]
• Output 1: In Read Cycle
• Output 2: On Match (or On Good Read) Output Mode: Pulse (500ms)
• Output 3: Use as Ext. Illumination Strobe Fixed Light On Time: 100000μs Fixed Light Delay
Time: 5000μs
For how to set up the Output signal assignments, please refer to How to Assign the Output Signals on
page 2 - 10.
 <Timing Chart>
1. Trigger input
(TRIG signal)
2. Output1
In Read Cycle
3. Output2
Match
(or Good Read)
4. Output3
Use as Ext.
Illumination Strobe
V430-F Series Auto Focus Multi Code Reader User Manual for Communication Settings (Z407-E1)
2 Controlling Operation and Data Output with Parallel
Setting Value
External Strobe
Service Message is not used.
1 to 100000μs
The signal is ON during imaging only for the time set.
1 to 100000μs
The signal turns ON during imaging only after the time set.
ON
Read executed by Trigger Input.
OFF
ON
In Read Cycle
OFF
ON
OFF
ON
From 5ms after start of Read Cycle, ON for 100ms.
OFF
ON for 500ms at 2000ms intervals.
Description
Turns ON on Good Read.