Omron V430-F Series User Manual For Communication Settings page 57

Code reader, auto focus multi code reader
Hide thumbs Also See for V430-F Series:
Table of Contents

Advertisement

 MXL/SLC Input Assembly (102) Other after 102
Output when the timing of the Device Status - InReadCycle bit turning from ON to OFF.
Trigger
Trigger
Acknowledged
Exposure Done
Decoding
Data is Ready
Read Cycle Pass
Read Cycle Fail
Decode Date
(1) Reading starts at the rising edge of the Trigger.
(2) Trigger Acknowledged turns ON when Trigger ON is detected and turns OFF when Trigger
OFF is detected.
(3) ExposureDone turns OFF when exposure starts and turns ON when exposure completes.
(4) Decoding is ON during decoding processing. The Decoding process overlaps the Exposure
process.
(5) Data is Ready turns ON at the same time Decode Data / Read Cycle Pass or Read Cycle is
confirmed.
(6) Read Cycle Pass turns ON when there is a Good Read and Read Cycle Fail turns ON when
there is a No Read. The Read data is stored in Decode Data.
Additional Information
There can be up to a 10ms delay in the Output timing of the Symbol data.
(7) When the next Trigger is detected, Data is Ready turns OFF.
V430-F Series Auto Focus Multi Code Reader User Manual for Communication Settings (Z407-E1)
3 Controlling Operation and Data Output with Ethernet
Executes Read
ON
OFF
Turns ON if Trigger ON is detected and OFF if OFF is detected.
ON
OFF
Turns OFF during Exposure and ON after Exposure Complete.
ON
OFF
Turns ON during Decode process (including Exposure).
ON
OFF
Turns ON at same time Read Cycle Pass/Read Cycle Fail/Decode Data are confirmed.
ON
OFF
Turns ON on Good Read.
ON
OFF
ON
OFF
Turns ON on No Read.
Read data
Read data
3 - 13
3