Omron V430-F Series User Manual For Communication Settings page 127

Code reader, auto focus multi code reader
Hide thumbs Also See for V430-F Series:
Table of Contents

Advertisement

32 bit
Total ReadCycle Time
Number of Decodes in Read
Cycle
Number of Decode Reports
RAW Input Data
Output Assembly (Instance ID: 197)
The Output Assembly can send several commands to the reader.
Output Assembly Member Structure
COMMANDS
Member Description
• Commands
An explanation of commands that can be sent to the reader.
Bit
0
1
2
3
4
5
6
7
8
9
10
11
12
13 - 31
・Run Mode
Enables / Disables Read Cycle. Immediately after the reader is started, Read Cycle will be enabled
regardless of this command.
0 = Read Cycle Disabled. No trigger can be accepted. However, other commands can be executed.
1 = Enables Read Cycle.
・Trigger
Executes Read. The reader recognizes this bit changing from 0 to 1 as the rising edge of the trigger
and its change from 1 to 0 as the falling edge of the trigger.
・Enable MatchCode
Enable / Disable the Matchcode function. Immediately after the reader is started, the previously
saved setting is in effect regardless of this command.
0 = Disable Matchcode function.
1= Enable Matchcode function.
V430-F Series Auto Focus Multi Code Reader User Manual for Communication Settings (Z407-E1)
Member Name
Data Type
Member Name
Run Mode
Trigger
Enable Match Code
Reset General Fault
Clear No Read ReadCycle Count
Clear Mismatch ReadCycle Count
Clear NoRead Count
Clear Trigger Count
Clear Match Code Count
Clear Mismatch Count
Output 1
Output 2
Output 3
Reserved
Bit Number
Data Length
0 - 15
2 byte
0 - 7
1 byte
0 - 7
1 byte
16 byte
Size (Bytes)
4
Total Size: 4 Bytes
Command
Appendices
Byte Offset
44 byte
A
A - 29

Hide quick links:

Advertisement

Table of Contents
loading