2 Controlling Operation and Data Output with Parallel
The following settings are set independent for each Output signal.
Change the Output signal number selection as needed for your application.
• WebLink - Setup - Gear Icon - Advanced Settings - I/O - Trend Options (Output 1, 2, 3)
Setting Item
Trend Analysis
Mode
Number of Triggers
Number to Output
On
Decodes per Trigger
Threshold
Below is an Output assignment example and Timing chart.
[Example assignment of OUTPUT signals]
• Output 1: In Read Cycle
• Output 2: Trend Analysis Output Mode: Pulse
2 - 14
Setting Value
Mismatch
Mismatch:
Turns ON when the number of Mismatches for the most recent
No Read
Number of Triggers cycle reaches the number set for Number
Decodes per
to Output On.
Trigger
No Read:
Turns ON when the number of No Reads for the most recent
Number of Triggers cycle reaches the number set for Number
to Output On.
Decodes per Trigger:
Turns ON when the Number Of Decodes for the most recent
Number of Triggers cycle reaches the number set for Number
to Output On.
0 to 255
The number of triggers in the Trend Analysis.
For example, if you set this to 25, the Trend Analysis will be done
for the most recent 25 trigger inputs.
0 to 255
This is the threshold for turning on the Output signal Trend
Analysis is assigned to.
For example,
Trend Analysis Mode : No Read,
Number of Triggers : 25,
Number to Output On : 4
With these settings, the output signal turns ON when there are 4
No Read in the last 25 triggers.
0 to 65535
When the number of codes read within the Read Cycle falls below
the Decodes per Trigger threshold, the Output signal turns ON.
Setting Example
Read Cycle:
Trigger - Mode : External Edge
End of Read Cycle - Mode : Timeout
Capture Mode - Captures Mode : Continuous
I/O:
Decodes per Trigger Output - Decodes/Trigger Status :
Enabled
Trend Analysis (Output 1) - Trend Analysis Mode : Decodes
per Trigger
Trend Analysis (Output 1) - Number of Triggers : 1
Trend Analysis (Output 1) - Number to Output On : 1
Trend Analysis (Output 1) - Decodes per Trigger : 10
10 or more Reads in the Read Cycle : Signal OFF
9 or less Reads in the Read Cycle : Signal ON
V430-F Series Auto Focus Multi Code Reader User Manual for Communication Settings (Z407-E1)