Mitsubishi CR750 Series Instruction Manual page 77

Force sense function
Table of Contents

Advertisement

P2.Z=P2.Z+100
Mvs P2
End
■ Description
Work complete conditions are defined for Mo trigger 1 with the Def MoTrg command.
1)
Force sense control is enabled after enabling Mo trigger 1, and insertion work is started.
2)
If insertion work is not complete within 5 seconds of work starting, a 9100 error is output, and insertion
3)
work is stopped.
If insertion work is successfully completed, M_MoTrg(1)=1, and interrupt processing (label: *XOK) is
4)
performed.
8 Using the Force Sense Function (Programming)
'Target position determined as position +100 mm in Z-direction
from current position
Force Sense Detection 8-67

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cr750-qCr751 seriesCr751-dCr751-qCr750-d

Table of Contents