Item No.
U034
Adjustment: Leading edge registration adjustment
1. Press the system menu key.
2. Press the start key to output a test pattern.
3. Press the system menu key.
4. Select the item to be adjusted.
[LSU Out Top]
Display
MPT(L)
MPT Half(L) Paper feed from MP tray
Cassette(L)
Cassette
Half(L)
Duplex(L)
Duplex
Half(L)
MPT(S)
MPT
Half(S)
Cassette(S) Paper feed from cassette
Cassette
Half(S)
Duplex(S)
Duplex
Half(S)
(L): When large size paper is used (218 mm or more in width of paper).
(S): When small size paper is used.
Description
Paper feed from MP tray
Paper feed from cassette
Paper feed from cassette
Duplex mode (second)
Duplex mode (second)
Paper feed from MP tray
Paper feed from MP tray
Paper feed from cassette
Duplex mode (second)
Duplex mode (second)
1-3-37
Description
Setting
range
-3.0 to 3.0
-3.0 to 3.0
-3.0 to 3.0
-3.0 to 3.0
-3.0 to 3.0
-3.0 to 3.0
-3.0 to 3.0
-3.0 to 3.0
-3.0 to 3.0
-3.0 to 3.0
-3.0 to 3.0
-3.0 to 3.0
2N8/2N7
Initial
Change in
setting
value per step
0
0.1 mm
0
0.1 mm
0
0.1 mm
0
0.1 mm
0
0.1 mm
0
0.1 mm
0
0.1 mm
0
0.1 mm
0
0.1 mm
0
0.1 mm
0
0.1 mm
0
0.1 mm