Electrical Power Connections; Voltage Check; Surrounding Area; Temperature Setpoints - Jackson TempStar Series Installation, Operation And Service Manual

Door-type dishmachines
Table of Contents

Advertisement

INSTALLATION
ELECTRICAL POWER
CONNECTIONS
Disconnect electrical
power supplies and
lockout/tagout in
accordance with
appropriate procedures
and codes at the
disconnect switch.
!
CAUTION

VOLTAGE CHECK

i

SURROUNDING AREA

TEMPERATURE
SETPOINTS
07610-002-23-32-AC
Electrical and grounding conductors must comply with the applicable portions of the
National Electric Code ANSI/NFPA 70 (latest edition) and/or other electrical codes.
The data plate is located on the right side of the dishmachine. Refer to the data plate for
machine operating requirements, machine voltage, total amperage and serial number.
1. Open the control box by using a phillips screwdriver to remove the four screws on
the front cover of the control box.
2. Install 3/4" conduit into the pre-punched holes in the back of the control box.
3. Route power wires and connect to power block and grounding lug.
4. Install the service wires (L3 for 3-Phase only) to the appropriate terminals as they
are marked on the terminal block.
5. Install the grounding wire into the lug provided.
6. Tighten the connections.
It is recommended that "DE-OX" or similar anti-oxidation agent be used on
NOTICE
all power connections.
CAUTION! Improperly connecting external devices can cause damage to the
machine and/or electrical infrastructure! See Addendum for a wiring guide.
Ensure that the power button is in the off position and apply power to dishmachine.
Check the incoming power at the terminal block and ensure it corresponds with the
voltage listed on the data plate. If not, contact a qualified service agency to examine
the problem. Do not run dishmachine if voltage is too high or too low. Shut off the
service breaker and advise all proper personnel of the location of the breaker and
any problems. Replace the control box cover and tighten-down the screws.
This is a commercial dishmachine and reaches temperatures that can exceed
those generated by a residential machine. Surrounding countertops, cabinets, flooring
material, and subfloor material must be designed and/or selected with these higher
temperatures in mind.
Any damage to surrounding area caused by heat/moisture to materials that
NOTICE
are not recommended for higher temperatures will not be covered under
warranty or by the manufacturer.
The temperature setpoints on this unit have been set at the factory. They should
only be adjusted by an authorized service agent.
INSTRUCTIONS
Ground
NOTICE
Imbalanced
wild leg goes
to L3.
13