INSTALLATION
ELECTRICAL POWER
CONNECTIONS
Disconnect electrical
power supplies and
lockout/tagout in
accordance with
appropriate procedures
and codes at the
disconnect switch.
If necessary, see
"Heaters" page for
phase conversion kit.
!
CAUTION

MOTOR ROTATION

!
CAUTION
CAUTION! On 3-Phase
machines only, correct
pump motor rotation
must be verified
before operation!
07610-003-61-42-V
Electrical and grounding conductors must comply with the applicable portions of the
National Electric Code ANSI/NFPA 70 (latest edition) and/or other electrical codes.
The data plate is located on the right side of the machine. Refer to the data plate for
machine operating requirements, machine voltage, total amperage, and serial number.
1. Open the control box by using a phillips screwdriver to remove the four screws on
the front cover of the control box.
2. Install 3/4" conduit into the pre-punched holes in the back of the control box.
3. Route power wires and connect to power block and grounding lug.
4. Install the service wires (L3 for 3-Phase only) to the appropriate terminals as they
are marked on the terminal block.
5. Install the grounding wire into the lug provided.
6. Tighten the connections.
NOTICE
CAUTION! Improperly connecting external devices can cause damage to the
machine and/or electrical infrastructure! Click
On 3-Phase machines only, correct pump motor rotation must be verified before
the machine is operated. Failure to do so can result in damage to the machine and
components.
i
1. Follow the "Filling the Wash Tub" section.
2. Locate the wash pump motor and identify the arrow decal which shows the
correct motor rotation (if no decal is present, correct rotation is away from the
pump volute).
3. Flip the mode switch to "MANUAL" and start the machine.
4. Observe the rotation of impeller and quickly stop the machine.
5. If rotation is incorrect, disconnect electrical power and reverse the L1 and L2
connections at terminal block shown in the section above.
"DE-OX" or similar anti-oxidation agent should be used on all power
connections.
INSTRUCTIONS
Ground
here
for a wiring guide.
Pump Volute
NOTICE
Imbalanced
wild leg goes
to L3.
Impeller
11