Fault Message
065 HAMMER BANK FAN
FAULT
069 DATA CLEARED
080 POWER SUPPLY HOT
082 POWER SUPPLY 8.5V
FAILED
083 INTAKE FAN FAULT
084 POWER SUPPLY 48V
FAILED
085 CONTROLLER
VOLTAGE
086 CONTROLLER 15V
087 PLATEN OPEN
TIMEOUT
CLOSE PLATEN
088 CONTROLLER 23.5V
Table 12: Fault Messages
Operator
Explanation
Correctable?
Yes
Sensors cannot detect
current in fan circuit.
N/A
Appears when data is
cleared out of printer
after Cancel key has
been pressed.
No
Circuits are overheating
on the power supply
board.
No
Internal power failure.
Yes
Sensors cannot detect
current in fan circuit.
No
Internal power failure.
No
Controller voltage failure.
No
Controller voltage failure.
Yes
Forms thickness lever
has been open for at
least one minute.
No
Controller voltage failure.
Fault Correction Procedure
Solution
Power off the printer.
Check for obstruction of
vents and fan airway;
remove any obstructions.
Check for items beneath
the printer blocking cabinet
vents. Power back on the
printer. If this message
reoccurs, contact your IBM
service representative.
No action necessary.
Contact your IBM service
representative.
Contact your IBM service
representative.
Power off the printer.
Check for obstruction of
vents and fan airway;
remove any obstructions.
Check for items beneath
the printer blocking cabinet
vents. Power back on the
printer. If this message
reoccurs, contact your IBM
service representative.
Contact your IBM service
representative.
Contact your IBM service
representative.
Contact your IBM service
representative.
Close forms thickness
lever.
Contact your IBM service
representative.