Network Status - Panduit PAT1M4.0 Operation Manual

Automatic cable tie installation tools pdm4.0: dispenser phm: feeder hoses
Table of Contents

Advertisement

© Panduit Corp. 2018
When first accessing the Network and Setting pages on the PAT SYSTEM; or after approximately
30 minutes of inactivity, entry of a Username and Password is required. The default Username is
"Panduit PAT" and the default Password is "password".
15B: NETWORK STATUS
See Username and Password on Page 60 for username and password authentication.
The Network Status indicates the state of the Ethernet/IP connection. A table of Network
Status states is below.
PA27647A01_05
OPERATION MANUAL
ENGLISH
Module
Network
Settings
Summary
Requirement
No Power, No IP
The device is powered off, or is powered on but with no IP address
address
configured (Interface Configuration attribute of the TCP/IP Interface
Object).
No Connections
An IP address is configured, but no CIP connections are established,
and an Exclusive Owner Connection has not timed out.
Standby
At least one CIP connection (any transport class) is established, and
an Exclusive Owner Connection has not timed out.
An Exclusive Owner Connection for which this device is the target has
Connection
timed out, the network status indicator shall return to steady green
Timeout
only when all timed out Exclusive Owner connections are
reestablished.
Devices that support a single Exclusive Owner Connection shall
transition to steady green when subsequent Exclusive Owner
Connections are established
Timeout of connections other than Exclusive Owner Connections shall
not cause the indicator to flash red.
The Flashing Red state applies to target connections only. Originators
and CIP Routers shall not enter this state when an originated or routed
CIP connection times out.
Duplicate IP
For devices that support duplicate IP address detection, the device
has detected that (at least one of) its IP addresses are already in use.
Self-Test
The device is performing its power-on self-test (POST); During POST
the network status indicator shall alternate flashing green and red.
PAT Web Browser Interface

Network Status

Connected
Device Name
Panduit PAT
CHANGE
Network Settings
DHCP
CHANGE
IP Address
192.168.1.123
Network Mask
255.255.255.0
Gateway IP
192.168.1.99
Page: 61 of 64